Getting Started Material and Tools Required:
WarmlyYours Snow Melt Mats and/or Cables
Controller, sensor(s), relay panel and Plaque
Custom Design Layout (provided FREE with order)
Digital Ohms Meter & 500 VDC Digital Megohm Meter (Megger)
Amp Meter, Plastic cable ties, & Scissors
Please call WarmlyYours (800) 875-5285 for 24/7 installation and technical
support if needed.
Step 1 – Electrical Rough-In
The electrician will supply appropriately sized dedicated breakers for each
heater circuit (30mA trip GFPE breakers may be required by NEC or local
codes). The relay panel(s), if necessary, must be installed, and power routed
from the breakers to the relay panel(s). Any junction box(es) required for cold
lead extensions/splicing should be installed at this time. The thermostat and its
junction box, relay panel(s), if necessary, and associated wiring & conduit should
be installed.
Step 2 – Mat/Cable Heater Installation
When material order shipment arrives, use ohms meter to test each mat heater
(between the two conductors), and verify number with the UL tag. Also, test
each heating mat for megohms (between conductor and yellow/green ground
wire). The 500 VDC Megohm Meter tests for insulation resistance around the
conductor(s), and should read infi nite, OL, or a minimum of 10 megohms.
Step 3 – Basic Preparation
The concrete installer ensures that the base has at least 8” to 12” of crushed
rock aggregate that has been spread, and rolled over or tamped down. A 4” to
12” layer of sand is spread evenly over the aggregate. 2” polystyrene insulation
(or better) must be placed on top of the sand layer (insulation must never make
direct contact with heating cable). This insulation should also be placed vertically
around the perimeter of the slab to prevent “edge heat loss”. Heavy-gauge wire
mesh or rebar should be used for reinforcement (chicken wire is not acceptable).
This rebar, or wire mesh, may be propped up with wire chairs or concrete pavers.
1
2
3
Installing Floor Heating
Under Concrete Slabs
Page view 0
1 2

Summary of Contents

Page 1 - Under Concrete Slabs

Free Design Service • 24/7 Installation Support • No Nonsense™ Warranty •(800) 875-5285 • www.WarmlyYours.comGetting Started Material and Tools Req

Page 2

Free Design Service • 24/7 Installation Support • No Nonsense™ Warranty •(800) 875-5285 • www.WarmlyYours.comStep 4 – Heater & Sensor Placement

Comments to this Manuals

No comments